FLUKE MICROSCANNER2 MANUAL PDF

get started using the tester. For additional information, see the MicroScanner2 Cable Verifier. Users Manual on the Fluke Networks website. Safety. Warning. MicroScanner2 Cable Verifier. Accessing the Users Manual. This guide provides basic information to help you get started using the tester. For additional. View and Download Fluke MicroScanner 2 user manual online. Cable Verifier. MicroScanner 2 Test Equipment pdf manual download.

Author: Moogull Shaktilmaran
Country: Mauritania
Language: English (Spanish)
Genre: Finance
Published (Last): 11 March 2007
Pages: 178
PDF File Size: 10.46 Mb
ePub File Size: 14.33 Mb
ISBN: 153-9-21118-127-2
Downloads: 50919
Price: Free* [*Free Regsitration Required]
Uploader: Akinosida

Fluke Networks warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media.

Fluke Networks does not warrant that software will be error free or operate without interruption. Table of Contents Title Page Introduction See explanations in the manual. This equipment is intended for Fluke Networks. Micriscanner2 the tester if cause burns or explode. If exposure to chemicals appear.

Figures 1 and 11 show examples of this occurs, clean with water and get medical aid. Do not put in sunlight. LCD display with backlight. Navigates through screens and changes settings. The rightmost segments indicate the shield. Without this termination, the tester cannot detect crossed wires or crossed pairs. Open on Twisted Pair Cabling Figure 6 shows an open mjcroscanner2 wire 4.

Notes If only one wire in a pair is open and a wiremap adapter or remote ID locator is not connected, both wires are shown as open. Mabual shorted Figure 8 shows that wires 3 and 4 are crossed. The the pin wires flash to indicate the fault. The cable length is The pin numbers flash to indicate the fault.

This crossed pair is likely caused ,icroscanner2 mixing A and B cabling.

Fluke MicroScanner 2 User Manual

Detection of crossed pairs requires a far-end adapter. The split pair flashes to indicate the fault. In a split pair, continuity from end to end is correct, but is made with wires from different pairs.

Length is not shown because the voltage interferes with length measurements. Only the first bridge tap detected is reported. The distance to a bridge tap is approximate because multiple reflections from the bridge tap interfere with length measurements. Note Bridge taps more than ft m from the tester or taps less than 16 ft mnual m long may not be Dashes are shown if the tester cannot Ethernet Port Detected measure the length.

This mankal occur if the port does not The tester can detect active and inactive Ethernet ports, as produce reflections. On the individual results microscannsr2, shorts are shown only when they are between wires in a pair.

  ELTON TRUEBLOOD THE HUMOR OF CHRIST PDF

MicroScanner Cable Verifier Users Manual The tester cannot measure length past the bridge tap Connecting to Telephone Networks Wired in because reflections from the bridge tap connections Star Topologies interfere with measurements.

Telephone cables wired in a star topology Figure 16 are connected together at a bridge tap at the distribution If you connect the tester to the bridge tap, the tester center. For a correct length reading, connect the tester and wiremap adapter as shown.

Topologies Telephone cables wired in a bus topology Figure 17 Connect the wiremap adapter or ID locator to the connect the wall outlets in series. Locations of the tester and wiremap adapter may be swapped.

MicroScanner2 Getting Started Guide, Rev. 1 | Fluke Networks

For cabling not terminated with an F-connector, use an adapter or hybrid patch cord to connect to the cabling. Figure 19 shows a good coaxial cable Open on Coaxial Cabling egk Refer to Figures 24 and Connect the tester to the cable. Using the Toner Notes If you cannot locate the IntelliTone signal on 2-conductor cables, the cable may be shorted.

Use the tester to check for shorts. See pages 11 and Use the probe to isolate the tone source in the cable bundle or at the patch panel. Using the Toner in IntelliTone Mode LEDs show the wiremap. Clean the display with glass cleaner and a soft, lint-free cloth.

If Table 2 does not help you solve a problem with the tester, contact Fluke Networks for additional help. For the latest list of options and accessories visit the Fluke Networks website at www. Specifications Specifications Specifications apply at 23 C 73 Funless otherwise noted. Test connectors F-connector for coaxial cable. The wiremap is drawn with proportional length to visually indicate the approximate location of faults. Detects the advertised speed of MicroScanner Cable Verifier Users Manual Regulatory Information This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the manual, may cause interference to radio communications.

It has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15, Subpart J of the FCC rules, which are designed to provide reasonable protection against such interference Diagnosing Wiremap Faults Appendix A lists the typical causes of wiremap failures. Split Pair Wires connected to wrong pins at connector or punchdown Open block. Index cable tests Symbols coaxial cabling, 28 “? Index testing —R— coaxial cabling, 28 registration, 1 twisted pair cabling, 11 remote ID locator, 10, 22 toner, 32 replacement parts, 42 analog mode, 35 RJ11 jack, 10 IntelliTone mode, 32 SmartTone function, 35, 36 —S— troubleshooting safety information, 3, 39 cabling faults, 47 serial number, 41 the tester, MicroScanner Cable Verifier Users Manual split pair, 15 telephone voltages, 16 —U— universal adapter, 10 —V— version information, 41 voltage detection, 5, 16 —W— wiremap adapter, Page of 60 Go.

  HARIVANSH PURAN PDF

Page 33 – Connecting to a Telephone Network Wired Page 34 – Connecting to Telephone Networks Wired i Page 35 – Connecting to a Telephone Network Wired All product names are trademarks of their respective companies.

Table of Contents Add to my manuals Add. Page 2 Fluke Networks warrants that software will operate substantially in nanual with its functional specifications for 90 days and that it has been properly recorded on non-defective media.

FLUKE MICROSCANNER 2 USER MANUAL Pdf Download.

Results Screens for Individual Wire Pairs Using The Toner Refer to Figures 24 and Specifications Specifications Specifications Specifications apply at 23 C 73 Fmaunal otherwise noted.

Performance Specifications The wiremap is drawn with proportional length to visually indicate the approximate location of faults. Regulatory Information MicroScanner Cable Verifier Users Manual Regulatory Information This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the manual, may cause interference to radio communications.

Diagnosing Wiremap Faults Appendix A: Index Index cable tests Symbols coaxial cabling, 28 “? Page 59 Index testing —R— coaxial cabling, 28 registration, 1 twisted pair microsscanner2, 11 remote ID locator, 10, 22 toner, 32 replacement parts, 42 analog mode, 35 RJ11 jack, 10 IntelliTone mode, 32 SmartTone function, 35, 36 —S— troubleshooting safety information, 3, 39 cabling faults, 47 serial number, 41 the tester, Page 60 MicroScanner Cable Verifier Users Manual split pair, 15 telephone voltages, 16 —U— universal adapter, 10 —V— version information, 41 voltage detection, 5, 16 —W— wiremap adapter, Comments to this Manuals Your Name.

Enter text from picture: By pressing ‘print’ button you will print only current page. To print the manual completely, please, download it. Don’t show me this message again.

Got it, continue to print. Don’t have an account?

Author: admin