ASTM E243 PDF

British Standards (BS) and American Standards (ASTM) relating to magnetic flux ASTM E Electromagnetic (eddy current) testing of seamless copper and. ASTM-E Standard Practice for Electromagnetic (Eddy Current) Examination of Copper and Copper-Alloy Tubes – electromagnetic (eddy current) testing; NDT . Standard Number, ASTM E – Title, Standard Practice for Electromagnetic ( Eddy Current) Examination of Copper and Copper-Alloy.

Author: Braran Zujar
Country: Saudi Arabia
Language: English (Spanish)
Genre: Medical
Published (Last): 25 October 2018
Pages: 79
PDF File Size: 6.38 Mb
ePub File Size: 11.44 Mb
ISBN: 494-6-52172-306-6
Downloads: 85120
Price: Free* [*Free Regsitration Required]
Uploader: Mikazil

Our standard end finishing is available in three different options see chart. Link to Active This link will always route to the current Active version of the standard. Relevant indications are those which result from nonacceptable discontinuities.

See Price Sheet for packaging multiples. This practice may be used as a guideline for the examination, by means of internal probe examination coil systems, of installations using tubular products where the outer surface of the tube is not accessible.

Any indication above the reject level that is believed to be irrelevant shall be regarded as unacceptable until it is demonstrated by re-examination or other means to be irrelevant see Signals can be produced by discontinuities located either on the external or internal surface of the tube or by discontinuities totally contained within the walls.

These procedures may be used for tubes beyond the size range recommended, upon contractual agreement between the purchaser and the manufacturer. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Signals can be produced by discontinuities located either on the external or internal surface of the tube or by discontinuities totally contained within the walls.

  AMAME JULIE KENNER PDF

Since the density of eddy currents decreases nearly exponentially as the distance from the external surface increases, the response to deep-seated defects decreases.

Individual packaging and bulk packaging available. These procedures may be used for tubes beyond the size range recommended, upon contractual agreement between the purchaser and the manufacturer. Any indication above the reject level that is believed to be irrelevant shall be regarded as unacceptable until it is demonstrated by re-examination or other means to be irrelevant see Note 1-This practice may be used as a guideline for the examination, by means of internal probe test asttm systems, of installations using tubular products where the outer surface of the tube is not accessible.

Cerro offers over 1, different lineset combinations based on: These procedures may be used for tubes beyond the size range recommended, upon contractual agreement between the purchaser and the manufacturer.

On-line eddy current examining would not be subject to end effect. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

ASTM Electromagnetic Inspection Standards

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. See E for additional details regarding the in-situ examinations using internal probes. Historical Version s – view previous versions of standard. Irrelevant indications can mask unacceptable discontinuities. The liquid line is normally not insulated, but can be special ordered to be insulated.

  ASTM D1876 PDF

On-line eddy current examining would not be subject to end effect. For such applications, the technical differences associated with the use of internal probe coils should be recognized and accommodated.

Electromagnetic NDT Portal

The effect of foreign materials on the tube surface and signals due to tube supports are typical of the factors that must be considered. Split system air conditioning Ice makers Chilled water systems. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. For such applications, the technical differences associated with the use of internal probe coils should be recognized and accommodated.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not aastm as part of the standard.

These procedures may be used for tubes beyond the size range recommended, upon contractual agreement between the purchaser and the manufacturer.

copper tubing and other products

Relevant indications are those which result from nonacceptable discontinuities. Signals can be produced by discontinuities located either on the external or internal surface of the tube or by discontinuities totally contained within the walls. R A R RA. BoxArlingate Ln.

Author: admin